Walk In Fume Hood
Walk In Fume Hood

Walk In Fume Hood

MOQ : 1 Piece

Walk In Fume Hood Specification

  • Temperature Resistance
  • Up to 180C
  • Speed Range
  • Variable airflow depending on blower specification
  • Glass Type
  • Tempered Safety Glass (Sliding Sash Front)
  • Power Supply
  • Electric
  • Display Type
  • Analog/Digital (Optional)
  • Control Type
  • Manual/Automatic (Optional) Controls
  • Shape
  • Rectangular Enclosure
  • Features
  • Acid resistant, Chemical resistant, Walk-in structure, Illuminated work area, Efficient exhaust system
  • Type
  • Walk In Fume Hood
  • Dimension (L*W*H)
  • 1200 mm x 900 mm x 2400 mm (customizable)
  • Equipment Type
  • Laboratory Fume Extraction System
  • Equipment Materials
  • GI (Galvanized Iron) Sheet with Epoxy Coating
  • Power
  • 220V/50Hz, Single phase
  • Voltage
  • 220 V
  • Material
  • Epoxy-coated Steel, FRP Lining
  • Application
  • Chemical Laboratory, Pharmaceuticals, Research Institutes
  • Capacity (Ltr)
  • 150-300 Liters (depends on size)
  • Noise Level
  • < 65 dB
  • Sockets
  • Electrical sockets fitted inside
  • Exhaust System
  • High efficiency centrifugal blower with ducting
  • Optional Accessories
  • Gas/vacuum taps, Water faucets, Cup sinks, Airflow monitor
  • Internal Lining
  • Chemical resistant FRP or Polypropylene
  • Lighting
  • LED/fluorescent light fitting included
  • Construction
  • Double wall construction for durability and safety
  • Worktop
  • Granite/epoxy-resin worktop
  • Sash Operation
  • Vertical/horizontal sliding sash
  • Airflow Velocity
  • 0.4 - 0.6 m/s at front opening
 

Walk In Fume Hood Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 10 Pieces Per Month
  • Delivery Time
  • 5-7 Days
  • Main Domestic Market
  • All India
 

About Walk In Fume Hood



Grab Yours now-on Clearance! The Walk In Fume Hood is trending across leading chemical laboratories, pharmaceuticals, and research institutes in India. Experience an enlightened approach to safety with this lofty, magnificent rectangular enclosure, crafted from epoxy-coated steel and GI sheet with magnificent FRP lining. Engineered for peak efficiency, it features a chemical-resistant interior, vertical/horizontal sliding tempered glass sash, robust LED/fluorescent lighting, acid/chemical resistance, and a high-efficiency exhaust system. Benefit from manual or automatic controls, customizable dimensions, and illuminated workspaces. Optional accessories include airflow monitors for maximum protection. Hurry, secure this elite laboratory essential today!

Ideal Usage & Competitive Advantages of the Walk In Fume Hood

This Walk In Fume Hood is extensively used by research institutes, chemical laboratories, and the pharmaceutical sector for safe fume extraction and enclosed handling of hazardous substances. Its primary competitive advantages include a robust double-wall construction, customizable size, superior chemical resistance, and variability in airflow control. The surface of application is tailored for environments handling aggressive chemicals, volatile fumes, or acids, guaranteeing a safe and enlightened workspace for your research or processing needs.


Payment, Export Markets & Supply Strengths for Walk In Fume Hood

The Walk In Fume Hood is supplied with flexible payment terms suitable for diverse clients. Shipped Goods are securely packed for international and domestic dispatch, targeting major export markets such as Asia, the Middle East, and Europe. Our packing & dispatch process ensures product integrity throughout transit. With substantial monthly supply ability, we guarantee all units reach their destination swiftly and efficiently, making us a premier exporter, supplier, and manufacturer in India for laboratory fume extraction systems.


FAQ's of Walk In Fume Hood:


Q: How does the Walk In Fume Hood ensure operator safety?

A: The Walk In Fume Hood features a double wall construction, chemical-resistant FRP or polypropylene lining, and a high-efficiency exhaust system with a centrifugal blower. It also includes tempered safety glass sashes and integrated airflow monitoring, ensuring the operator's safety from harmful fumes and chemicals.

Q: What are the customization options for dimensions and accessories?

A: The Walk In Fume Hood can be customized according to the dimensions specified by the user. Optional accessories such as gas or vacuum taps, water faucets, cup sinks, and airflow monitors can be integrated to suit various laboratory requirements.

Q: When should I use a walk-in fume hood instead of a standard benchtop fume hood?

A: A walk-in fume hood is recommended for handling large equipment, processes involving voluminous or hazardous chemicals, or applications that require full-body entry, which cannot be accommodated by a traditional benchtop fume hood.

Q: Where can the Walk In Fume Hood be installed?

A: This fume hood is suitable for installation in chemical laboratories, pharmaceutical manufacturing units, research institutes, and educational facilities requiring enhanced air quality and operator safety during chemical processes.

Q: What is the process for ordering and shipping the Walk In Fume Hood?

A: After placing your order, we confirm details regarding dimension and optional features. The equipment is then manufactured, thoroughly tested, and securely packed before being shipped domestically or exported internationally.

Q: What are the main benefits of a high airflow velocity in this fume hood?

A: A high airflow velocity (0.4 - 0.6 m/s) at the front opening ensures efficient removal of hazardous fumes from the workspace, minimizing user exposure and maintaining a safe laboratory environment.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Laboratory Fume Hood Category

Distillation Fume Hood

Distillation Fume Hood

Minimum Order Quantity : 1 Piece

Control Type : Manual/Optional Electronic Controls

Capacity (Ltr) : 50 Litres

Power : 230V / 50Hz / 1 Phase

Type : Other, Distillation Fume Hood

Material : MS Sheet with FRP Lining

Chemical Lab Fume Hood

Chemical Lab Fume Hood

Minimum Order Quantity : 1 Piece

Control Type : Manual and Digital Available

Capacity (Ltr) : Custom/As Required

Power : 220V/50Hz, Single Phase

Type : Other, Chemical Lab Fume Hood

Material : Mild Steel, Stainless Steel, Glass

Laboratory Fume Hood

Laboratory Fume Hood

Minimum Order Quantity : 1 Piece

Control Type : Manual/Touch Control Panel

Capacity (Ltr) : Custom/Large workspace

Power : 220 W

Type : Other, Laboratory Fume Hood

Material : Epoxy coated steel with laminated work surface



Back to top