Vertical Laminar Airflow
Vertical Laminar Airflow

Vertical Laminar Airflow

MOQ : 1 Piece

Vertical Laminar Airflow Specification

  • Cleanliness Level
  • ISO Class 5 (Class 100)
  • Air Flow Direction
  • Vertical Downflow
  • Safety Features
  • Interlock for UV & Fluorescent lamp, Auto timer for UV
  • Construction
  • Jointless, Smooth Interior Finish
  • HEPA Filter Size
  • Standard (As per Dimension)
  • Noise Level
  • < 65 dB
  • Working Table Height
  • 700-750 mm
  • Illumination
  • LED/Fluorescent Lamp (In-built)
  • UV Lamp
  • Germicidal UV, 15W
  • Pre-Filter
  • Washable, 90% efficiency
 

Vertical Laminar Airflow Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Supply Ability
  • 10 Pieces Per Month
  • Delivery Time
  • 5-7 Days
  • Main Domestic Market
  • All India
 

About Vertical Laminar Airflow



Take advantage of this first-rate Vertical Laminar Airflow Cabinet, designed for radiant performance in demanding cleanroom environments. Constructed from lofty stainless steel 304 grade with a seamless, jointless finish, it guarantees longevity and optimal hygiene. The unit combines energy-efficient LED/fluorescent illumination, advanced washable pre-filter with 90% efficiency, and a high-precision HEPA filter for ISO Class 5 (Class 100) cleanliness. Featuring safe UV germicidal lamp with interlock, manual/touch controls, and low noise (<65 dB), this robust airflow solution supports laboratories, pharmaceuticals, and microbiology processes. Shop now and redeem spotless air assurance, delivered with reliable after-sales support across India.

Surface Applications & Uses of the Vertical Laminar Airflow Cabinet

This prominent Vertical Laminar Airflow Cabinet delivers contaminant-free surfaces, ideal for laboratories, pharmaceutical setups, and cleanroom environments. Used by microbiologists, research scholars, and quality control teams, it ensures ISO Class 5 conditions for sample preparations, culture work, and aseptic procedures. Its sturdy construction and radiant surface make it suitable for direct placement in microbiology labs, pharmaceutical R&D, and sterile manufacturing areas, guaranteeing a controlled environment for accurate results.


Supply Ability, Samples & Order Delivery for Laminar Airflow Cabinet

The laminar airflow cabinet is efficiently dispatched nationwide, with bulk supply capabilities ensuring timely order completion for large requirements. Customers can request sample units before purchase to validate performance and suitability. Delivered as per confirmed order schedules, payments are flexible, accommodating standard business terms. Our professionalism assures all units are delivered and installed as per client timelines, supported by comprehensive service and guidance throughout the acquisition process.


FAQ's of Vertical Laminar Airflow:


Q: How does the Vertical Laminar Airflow Cabinet maintain ISO Class 5 cleanliness?

A: The cabinet utilizes a combination of a washable pre-filter with 90% efficiency and a removable HEPA filter (99.97% efficiency at 0.3 micron) to ensure ISO Class 5 (Class 100) cleanliness, keeping work surfaces free from airborne contaminants.

Q: What materials are used in the construction of the airflow cabinet?

A: Mainly constructed from stainless steel 304 grade for the main body and powder coated steel for the exterior, it features a smooth, jointless interior and tempered glass side panels, ensuring high durability and sterile work conditions.

Q: Where can this vertical laminar airflow system be applied?

A: It is widely used in laboratories, microbiology settings, pharmaceutical industries, and cleanroom environments where contamination control and a sterile workspace are essential.

Q: How does the UV germicidal lamp enhance safety during operations?

A: The built-in 15W germicidal UV lamp can be operated with an interlock system and auto timer, ensuring user safety by preventing simultaneous operation with the fluorescent lamp and limiting UV exposure as required.

Q: What are the power and control options for this equipment?

A: The airflow cabinet operates on 220 V AC single-phase power with a consumption of 450W. Users can choose between manual switch or touch control for operation, with analog or digital displays available depending on the model.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Laboratory Furniture Category

Laboratory Exhaust System

Laboratory Exhaust System

Minimum Order Quantity : 1 Piece

Furniture Type : Other, Laboratory Equipment

Room Type : Other, Laboratory, Research Facilities

Width : 6001200 mm (customizable)

Metals Type : Other, Stainless Steel

Folded : NO

Lab Furniture

Lab Furniture

Minimum Order Quantity : 1 Piece

Furniture Type : Other, Laboratory Workbench

Room Type : Other, Laboratory

Width : 1200 mm (customizable)

Metals Type : Other, Stainless Steel, CRCA Steel

Folded : NO

R & D Lab Furniture

R & D Lab Furniture

Minimum Order Quantity : 1 Piece

Furniture Type : Other, Modular Laboratory Furniture

Room Type : Other, Research Lab

Width : 600 mm / Customizable

Metals Type : Other, Mild Steel

Folded : NO



Back to top